dcs800工业传动专门为工业应用设计,尤其用于在食品饮料、转炉炼钢、拔丝机、搅拌器、挤出机、实验台、滑雪缆车、金属、水泥、采矿业、纸浆和造纸、印刷等工业中的应用以及像直流充电器或磁铁一样的非旋转应用。
abb直流调速器维修dcs800系列:
dcs800-s01-0020-05、dcs800-s01-0045-05、dcs800-s01-0065-05
dcs800-s01-0090-05、dcs800-s01-0125-05、dcs800-s01-0180-05
dcs800-s01-0230-05、dcs800-s01-0315-05、dcs800-s01-0405-05
dcs800-s01-0470-05、dcs800-s01-0610-05、dcs800-s01-0740-05
dcs800-s01-0900-05、dcs800-s01-1190-05、dcs800-s01-1200-05
dcs800-s01-1500-05、dcs800-s01-2000-05、dcs800-s02-0025-05
dcs800-s02-0050-05、dcs800-s02-0075-05、dcs800-s02-0100-05
dcs800-s02-0140-05、dcs800-s02-0200-05、dcs800-s02-0260-05
dcs800-s02-0350-05、dcs800-s02-0450-05、dcs800-s02-0520-05
dcs800-s02-0680-05、dcs800-s02-0820-05、dcs800-s02-1000-05
dcs800-s02-1190-05、dcs800-s02-1200-05、dcs800-s02-1500-05
dcs800-s02-2000-05、dcs800-s02-0025-05、dcs800-s02-0050-05
dcs800-s02-0075-05、dcs800-s02-0100-05、dcs800-s02-0140-05
dcs800-s02-0200-05、dcs800-s02-0260-05、dcs800-s02-0350-05
dcs800-s02-0450-05、dcs800-s02-0520-05、dcs800-s02-0680-05
dcs800-s02-0820-05、dcs800-s02-1000-05、dcs800-s02-1190-05
dcs800-s02-1200-05、dcs800-s02-1500-05、dcs800-s02-2000-05
案例分析
abb直流调速器故障分析:
1、变流器过热引起直流电机跳闸。
这个故障主要是生产过程中突然跳闸,会引起生产停产,而且没有预兆。故障原因一般见于夏天或者是环境温度较高的室内,变流器一般设定67度跳闸,57度预警(a105)。
处理:降低环境温度到30度以下,特别是夏天,关键之关键是紧固可控硅的压靠螺丝,可控硅3年以上的压片螺丝经热胀冷缩可能松动引起温度报警跳闸。
2、室内灰尘太大引起排线接触不良合不上闸。
abb最大的缺陷是冷却风机的设计缺陷,所有的风机都装在控制器下部,带入了极大的粉 尘,必须1个月一次用压缩空气吹扫,否则会造成电路板插接部分接触不良,常见故障是合不上闸,风机等准备信号输不出,原因是排线接触太脏,其实电路板完全没必要用风机冷却。