万通商务网
首页-产品目录

现货销售pa66 fg42a nc010 高粘度,食品级

其它参数:
产品介绍:

pa66 fg42a nc010 高粘度,食品级

 

 

 

zytel® fg42a nc010 | pa66 nylon resin

 

regional availability

north america, europe, south【敏感词】central america, near east/africa

 

processing

injection moulding, film extrusion, profile extrusion, sheet extrusion, other extrusion, coatable, casting

 

delivery form

pellets

 

additives

release agent

 

product text

zytel® fg42a is a high viscosity polyamide 66 for injection molding【敏感词】extrusion. it has improved break resistance for thick-walled parts. it has been developed for consideration into applications such as parts for the food industry.

 

food contact

this product is manufactured according to good manufacturing practice (gmp) principles【敏感词】generally accepted in food contact applications in europe【敏感词】the usa when meeting applicable use conditions. for details, individual compliance statements are available from your dupont representative.

 

injection molding

preprocessing

drying recommended = yes, if moisture content of resin exceeds recommended level

drying temperature = 80℃

drying time, dehumidified dryer = 2-4 h

processing moisture content = <0.05 %

 

processing

melt temperature optimum = 290℃

melt temperature range = 280-300℃

mould temperature optimum = 70℃

mould temperature range = 50-90℃

 

profile extrusion

preprocessing

drying recommended = yes, if moisture content of resin exceeds recommended level

drying temperature = 80℃

drying time, dehumidified dryer = 4-6 h

processing moisture content = <0.05 %

 

processing

melt temperature optimum = 285℃

melt temperature range = 280-290℃

 

properties

rheological properties

dry / cond

unit

test standard

moulding shrinkage,parallel

1.4 / *

iso 294-4,2577

moulding shrinkage,normal

1.4 / *

iso 294-4,2577

mechanical properties

dry / cond

unit

test standard

tensile modulus

3100 / 1300

mpa

iso 527-1/-2

yield stress

83 / 55

mpa

iso 527-1/-2

yield strain

4.4 / 27

iso 527-1/-2

nominal strain at break

>50 / >50

iso 527-1/-2

charpy impact strength,23℃

n / n

kj/m2

iso 179/1eu

charpy impact strength,-30℃

n / n

kj/m2

iso 179/1eu

charpy notched impact strength,23℃

6 / 20

kj/m2

iso 179/1ea

charpy notched impact strength,-30℃

6 / 4

kj/m2

iso 179/1ea

thermal properties

dry / cond

unit

test standard

melting temperature,10℃/min

262 / *

iso 11357-1/-3

glass transition temperature,10℃/min

70 / -

iso 11357-1/-2

temp. of deflection under load,1.8 mpa

70 / *

iso 75-1/-2

temp. of deflection under load,0.45 mpa

200 / *

iso 75-1/-2

vicat softening temperature,50℃/h,50n

244 / *

iso 306

coeff. of linear therm. expansion,parallel

100 / *

e-6/k

iso 11359-1/-2

coeff. of linear therm. expansion,normal

100 / *

e-6/k

iso 11359-1/-2

flammability

dry / cond

unit

test standard

burning behav. at 1.5 mm nom. thickn.

hb / *

class

iec 60695-11-10

thickness tested

1.5 / *

mm

iec 60695-11-10

ul recognition

ul / *

-

-

burning behav. at thickness h

v-2 / *

class

iec 60695-11-10

thickness tested

3.0 / *

mm

iec 60695-11-10

ul recognition

ul / *

-

-

oxygen index

28 / *

iso 4589-1/-2

electrical properties

dry / cond

unit

test standard

relative permittivity,100hz

4.3 / 10

-

iec 60250

relative permittivity,1mhz

3.6 / 4.2

-

iec 60250

dissipation factor,100hz

150 / 2000

e-4

iec 60250

dissipation factor,1mhz

150 / 750

e-4

iec 60250

volume resistivity

1e13 / 1e11

ohm*m

iec 60093

electric strength

31 / -

kv/mm

iec 60243-1

other properties

dry / cond

unit

test standard

water absorption,2mm

8.5 / *

sim. to iso 62

humidity absorption,2mm

2.6 / *

sim. to iso 62

density

1140 / -

kg/m3

iso 1183

material specific properties

dry / cond

unit

test standard

viscosity number

280 / *

cm3/g

iso 307,1157,1628

rheological calc. properties

value

unit

test standard

density of melt

1010

kg/m3

-

thermal conductivity of melt

0.16

w/(m k)

-

spec. heat capacity melt

2790

j/(kg k)

-

ejection temperature

180

-

min. mould temperature

50

-

max. mould temperature

90

-

min. melt temperature

280

-

max. melt temperature

300

-

 

chemical media resistance

acids

√ acetic acid (5% by mass) (23℃)

√ citric acid solution (10% by mass) (23℃)

√ lactic acid (10% by mass) (23℃)

× hydrochloric acid (36% by mass) (23℃)

× nitric acid (40% by mass) (23℃)

× sulfuric acid (38% by mass) (23℃)

× sulfuric acid (5% by mass) (23℃)

× chromic acid solution (40% by mass) (23℃)

bases

× sodium hydroxide solution (35% by mass) (23℃)

√ sodium hydroxide solution (1% by mass) (23℃)

√ ammonium hydroxide solution (10% by mass) (23℃)

alcohols

√ isopropyl alcohol (23℃)

√ methanol (23℃)

√ ethanol (23℃)

hydrocarbons

√ n-hexane (23℃)

√ toluene (23℃)

√ iso-octane (23℃)

ketones

√ acetone (23℃)

ethers

√ diethyl ether (23℃)

mineral oils

√ sae 10w40 multigrade motor oil (23℃)

× sae 10w40 multigrade motor oil (130℃)

× sae 80/90 hypoid-gear oil (130℃)

√ insulating oil (23℃)

standard fuels

√ iso 1817 liquid 1 (60℃)

√ iso 1817 liquid 2 (60℃)

√ iso 1817 liquid 3 (60℃)

√ iso 1817 liquid 4 (60℃)

√ standard fuel without alcohol (pref. iso 1817 liquid c) (23℃)

√ standard fuel with alcohol (pref. iso 1817 liquid 4) (23℃)

√ diesel fuel (pref. iso 1817 liquid f) (23℃)

√ diesel fuel (pref. iso 1817 liquid f) (90℃)

× diesel fuel (pref. iso 1817 liquid f) (>90℃)

salt solutions

√ sodium chloride solution (10% by mass) (23℃)

× sodium hypochlorite solution (10% by mass) (23℃)

√ sodium carbonate solution (20% by mass) (23℃)

√ sodium carbonate solution (2% by mass) (23℃)

× zinc chloride solution (50% by mass) (23℃)

other

√ ethyl acetate (23℃)

× hydrogen peroxide (23℃)

× dot no. 4 brake fluid (130℃)

× ethylene glycol (50% by mass) in water (108℃)

√ 1% nonylphenoxy-polyethyleneoxy ethanol in water (23℃)

√ 50% oleic acid + 50% olive oil (23℃)

√ water (23℃)

× water (90℃)

× phenol solution (5% by mass) (23℃)

 

symbols used:

√ possibly resistant

defined as: supplier has sufficient indication that contact with chemical can be potentially accepted under the intended use conditions【敏感词】expected service life. criteria for assessment have to be indicated (e.g. surface aspect, volume change, property change).

 

× not recommended - see explanation

defined as: not recommended for general use. however, short-term exposure under certain restricted conditions could be acceptable (e.g. fast cleaning with thorough rinsing, spills, wiping, vapor exposure).

 

东莞市中嘉塑胶原料有限公司

免费会员

客服
高粘度阻尼脂
高粘度齿轮泵
pa66板pa66
pa66防火无卤
PA66含油尼龙板
pa66抗紫外线
pa66杜邦101l
尼龙pa66
PA66
pa66 70g33
登录
手机版 电脑版 下载安卓app 网址大全
万通商务网 版权所有©2020 u520.net